Control wires from the external relay controller box attach to terminal block positions 1 and 2. The AC-input PEM (shown in Figure A-2) and DC-input PEM (shown in Figure A-3) provide an input power connection on the front of the switch chassis to connect the site power source to the power supply. Table A-14 lists the specifications for the 1400 W AC-input power supply. All rights reserved. 10.The PDU power cable is designed for users who power their switch from a PDU. $2,250.00. Backordered. Mobile Nav Toggle Button Login/Register. ), Power supply is removed with redundancy disabled, System is booted with power supplies of different wattage installed and redundancy enabled, System is booted with power supplies of equal or different wattage installed and redundancy disabled. Note All 2500 W power supply power cords are 14 feet (4.3 meters) in length. Table A-17 lists the specifications for the 2500 W AC-input and DC-input power supplies. From an operational perspective, the DC-input power supply has the same characteristics as the AC-input version. Similar. 17.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. The PEMs have an illuminated power switch, current protection, surge and EMI suppression, and filtering functions. Unchecking this box will prevent you from subscribing to Ciena's communications. 6500 Packet-Optical Platform Designed for modernized network applications, the 6500-D7/S8 configurations converge comprehensive Ethernet, TDM, and WDM capabilities with packet/OTN switching and an intelligent control plane for cost-effective delivery of services. Positions 1 and 2 are used when the relay controller box contains a normally-open (NO) type of relay. If you fail to install two modules, you might receive spurious OUTPUT FAIL indications on the power supply. The appliance connector has a 90° left bend. The power supply output capacity is dependent on the number of AC power cords (1, 2, or 3) attached and the source AC voltage (110 VAC [low-line] or 220 VAC [high-line]) applied to the power supply inputs. Table A-22 lists the specifications for the 2700 W AC-input power supply. Products and services; Network insights; Sales and support; About us; All products Overview Features Specs 3D demo Support and next steps. All rights reserved. Note All 950 W power supply power cords have an IEC60320/C15 appliance connector at one end. Manufacturers Aastra Alcatel-Lucent Avaya Ciena Cisco E-Metrotel Ericsson Infinera Jabra Marconi Mitel Nortel Plantronics Polycom Siemens Yealink. 50/60 Hz (nominal) (±3 Hz for full range). Table A-11 1300 W DC-Input Power Supply Specifications. or Best Offer. 11.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. Note All 1300 W power supply power cords have an IEC60320/C19 appliance connector at one end. Green—Power supply fan is operating properly. The Catalyst 6509-V-E switch chassis is shipped with the two L brackets installed on the front sides of the chassis. Off—Power supply fan failure is detected. 2.For use with the Catalyst 6504-E switch only. The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to half-rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per slot. Table A-6 lists the 950 W AC-input power supply AC power cords specifications. Actual size of the wire needed is determined by the installer or local electrician. Table A-5 lists the power supply LEDs and their meanings. SAVE $32. The actual wire gauge size is determined by local electrical codes and restrictions. Table A-25 3000 W Power Supply Specifications. We are continually improving the user experience for everyone and applying the relevant accessibility standards. The ferrite bead is a passive device that limits high-frequency interference on interface and control cables, and is only required when you install the remote power-cycling feature that is supported by the 8700 Watt power supply. Table A-24 2700 W Power Supply AC Power Cords, Japan, North America 100–120 VAC operation. Ciena’s 6500 Packet-Optical Platform converges three comprehensive networking layers into a single platform to provide customizable service delivery from the access edge, along the backbone core, and across ocean floors. 2 AC-inputs per power supply. The 1000 W AC-input power supply (WS-CAC-1000W) is supported in the following Catalyst 6500 series switches: The 1000 W power supply (shown in Figure A-4) shares the same form factor as the 1300 W, 2500 W, 3000 W, 4000 W, and 6000 W AC-input power supplies. Note The 6000 W AC-input power supply is limited to 4000 W maximum output when it is installed in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB switch chassis. Take a look at all the Ciena products we supply and repair and please get in touch to request a quote or more information. Table A-9 lists the specifications for the AC power cords that are available for the 1000 W AC-input power supply. $22.00 shipping. © 2020 Cisco and/or its affiliates. Table A-31 lists the specifications for the AC power cords that are available for the 4000 W AC-input power supply. The table includes references to power cord illustrations. Table A-29 list the specification for the 4000 W DC-input power supply. There was a problem with your video. $1,843.88 $2,458.50 You ... Aruba S3500-48PF S3500-48P Mobility Access Switch with 48 10/100/1000BASE-T IEEE 802.3afPoE/802.3atPoE+ ports and optional uplink module slot (uplink module ordered separately). Take a look at all the Ciena products we supply and repair and please get in touch to request a quote or more information. Table A-16 lists the specifications for the AC power cords that are available for the 1400 W AC-input power supply. (add image attached – Ciena 6500-1) Download data sheet. From an operational perspective, the DC-input power supply has the same characteristics as the AC-input version. Lot of 5 World Wide Packets - Lightning Edge 311V Port Ethernet Switch W/O PSU . PTS PDH I/F 10X DIM 1:N PROTECTION: up to, unprotected, 1:1 protection or 1:5 protection, PTS MRO I/F 2xSFP+/14xSFP: 16x SFP (16xOC-3/12/STM-1/4, 8xOC-48/STM-16, 2x OC192/STM-64, or 16x100FX/GbE (10/100/1000BaseT), or 2x10GbE ports, PTS ETH I/F 40G 16 PORT (4X SFP+/16X CSFP) CIRCUIT PACK, PTS ETH I/F 100G 12 Port (2x QSFP28/10xSFP+) Circuit Pack. Note All 2500 W power supply power cords have an IEC60320/C19 appliance connector at one end. The circuit breaker or the fuse must be sized according to the power supply input power rating and any local or national electrical code requirements. When running redundant 4000 W, 6000 W, or 8700 W power supplies in Catalyst 6506 and Catalyst 6509 non-E series systems, if you remove the power supply in bay 1, the total system power will be reduced to 2940 W (70 A at 42 VDC) after 180 seconds (3 minutes). I understand I can unsubscribe at any time. Table A-5 950 W AC-Input and DC-Input Power Supply LEDs. This appendix describes the Catalyst 6500 series power supplies and provides their specifications. The effects of changing the power supply configurations are summarized in Table A-44 . Table A-29 4000 W DC-Input Power Supply Specifications. Note All 2700 W power supply power cords have an IEC60320/C19 appliance connector at one end. Table A-34 list the specifications for the 6000 W DC-input power supply. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. There was a problem with your video. Transceivers, Module Connectors, and Cables Specifications, 950W AC-Input and DC-Input Power Supplies, 1300W AC-Input and DC-Input Power Supplies, 2500W AC-Input and DC-Input Power Supplies, 2700W AC-Input and DC-Input Power Supplies, 4000W AC-Input and DC-Input Power Supplies, 6000W AC-Input and DC-Input Power Supplies, 950 W AC-Input and DC-Input Power Supplies, 1300 W AC-Input and DC-Input Power Supplies, 2500 W AC-Input and DC-Input Power Supplies, 2700 W AC-Input and DC-Input Power Supplies, 4000 W AC-Input and DC-Input Power Supplies, 6000 W AC-Input and DC-Input Power Supplies. Table A-7 lists the specifications for the 1000 W AC-input power supply. Table A-44 Effects of Power Supply Configuration Changes, Equal wattage power supply is inserted with redundancy enabled, Equal wattage power supply is inserted with redundancy disabled, Higher or lower wattage power supply is inserted with redundancy enabled, Higher or lower wattage power supply is inserted with redundancy disabled, Power supply is removed with redundancy enabled. Note The 4000 W DC-input power supply requires two source DC-inputs to be connected; it cannot operate with only one positive (+)/negative (-) source DC terminal pair installed. Terminal block material is rated at 120°C. If the larger wattage power supply fails, the smaller wattage power supply might not be able to handle the entire load by itself. The 6000 W AC-input, 6000 W DC-input, and the 8700 W AC-input power supplies are limited to 4000 W when they are installed in the Catalyst 6509-NEB switch chassis. The connector provides 42 VDC at a maximum of 17 A. Positions 2 and 3 are used when the relay controller box contains a normally-closed (NC) type of relay. Includes 1050W AC power supply. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. #CienaLife: A place where you can belong. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Please let us know if you encounter accessibility barriers on Ciena websites by contacting webchanges@ciena.com and we will get back to you in 2-5 business days. Table A-6 950 W AC-Input Power Supply Power Cords. If the difference between the two power supply’s output wattage is less than 10 percent of the higher output wattage power supply, redundancy is enabled. When powered with 110 VAC, it delivers only 1300 W. In addition, the power supply needs 16 A, regardless of whether it is plugged into 110 VAC or 220 VAC. Note With a fully populated Catalyst 6513 switch, two 2500 W power supplies are not fully redundant. Ciena’s 6500 Packet Transport System (PTS) addresses the growing need to maintain profitable delivery of TDM services while future-proofing investments toward an all-packet network modernization. Table A-33 6000 W AC-Input Power Supply Specifications. – The 1000 W power supply requires a 15 A or 20 A circuit. Note Because of form-factor differences, the 6000 W AC-input and the 6000 W DC-input power supplies cannot be installed in the Catalyst 6503, Catalyst 6503-E, and Catalyst 6504-E switch chassis. Optical Transmission. Similar. The 2500 W AC-input power supply (WS-CAC-2500W) and 2500 W DC-input power supply (WS-CDC-2500W) are supported in the following Catalyst 6500 series switches: The 2500 W power supplies, shown in Figure A-9 and Figure A-10, share the same form factor as the 1000 W, 1300 W, 3000 W, 4000 W, and 6000 W AC-input power supplies. If you need to install the ferrite bead, refer to Installing the Ferrite Bead. If the higher-wattage power supply fails, the lower-wattage supply might also shut down due to overcurrent protection to prevent damage to the lower-wattage power supply. SAVE $42. Table A-17 2500 W AC-Input Power Supply Specifications, 16 A maximum at 230 VAC at 2500 W output 16 A maximum at 120 VAC at 1300 W output, 3520 W (total input power) or 3.6 KVA (high-line operation). Table A-2 lists the compatibility of the power supplies with the Catalyst 6500 switch chassis. Worldwide Supply positions the refurbished Ciena CN 3930 as a way to provide a complete operations, administration and maintenance suite to build out support for your network even as you scale up with larger Ethernet deployments; many customers report a reduction of network operating costs when the Ciena CN 3930 is in use. The 1400 W power supplies (see Figure A-7) do not connect directly to source AC but use power entry modules (PEMs), located on the front of the Catalyst 6503 and Catalyst 6503-E switch chassis, to connect the site power source to the power supply located in the back of the chassis. To this day, network providers continue to add to their Time Division Multiplexing (TDM) infrastructure—an investment that is getting more expensive to run and operate. Table A-27 3000 W Power Supply AC Power Cords, Japan, North America (nonlocking plug) 200–240 VAC operation, Japan, North America (locking plug) 200–240 VAC operation, Japan, North America 100–120 VAC operation24. Table A-22 2700 W DC-Input Power Supply Specifications. This connector provides power to the WS-6509-NEB-UPGRD kit fan assembly through a power harness also provided in the kit. You can connect the DC-input power supply to the power source with heavy gauge wiring connected to a terminal block. Table A-21 2700 W AC-Input Power Supply Specifications. You can change the configuration of the power supplies to redundant or combined at any time. We also offer repair services on a large range of Ciena products. The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to half-rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per slot. Note The 2700 W AC-input power supply needs 220 VAC to deliver 2700 W of power. $113.69 Buy . The relay controller box switch, located next to the terminal block, allows you to match the power supply power control signal’s active state with the type of relay contained in the external relay controller box (either a normally-open type of relay or a normally-closed type of relay). 16.The PDU power cable is designed for users who power their switch from a PDU. Optical Transmission. Table A-1 Catalyst 6500 Series Power Supplies. When operating with 110 VAC, it delivers only 1400 W. In addition, the power supply needs 16 A, regardless of whether it is plugged into 110 VAC or 220 VAC. Table A-40 8700 W Power Supply Relay Controller Switch Settings and Operation. Each power supply input should have its own dedicated, fused-branch circuit: The 6000 W power supply can operate at either 2900 W or 6000 W depending on the number of AC power cords attached and the source AC voltage. Table A-30 lists the power supply LEDs and their meanings. Autoranging input with power factor correction (PFC). Table A-23 2700 W AC-Input and DC-Input Power Supply LEDs. Table A-39 lists the power supply LEDs and their meanings. Table A-11 lists the specifications for the 1300 W AC-input power supply. If the difference is greater than 10 percent, the lesser wattage power supply is disabled. Table A-41 8700 W Power Supply AC Power Cords. Power supply blank panel—The power supply blank panel must be installed on an unused power supply bay to maintain chassis airflow and EMI shielding. (The system had previously turned off the lower-wattage power supply. Table A-25 lists the specifications for the 3000 W AC-input power supply. It's free to sign up and bid on jobs. Catalyst 6500 Series Switch Installation Guide, View with Adobe Reader on a variety of devices. Although the power management feature allows you to supply power to all installed modules with two power supplies, redundancy is not supported in this configuration. Illustrated Parts List Ciena 6500 - This Parts Catalog or Illustrated Parts List is a detailed description of all spare parts that compose the product. 22.The PDU power cable is designed for users who power their switch from a PDU. Note The Catalyst 6500 series switches allow you to mix AC-input and DC-input power supplies in the same chassis. Networking Routers Switches. The 6500 Packet-Optical Platform (formerly called the Optical Multiservice Edge 6500 or OME 6500 during the product's time at Nortel) in telecommunication, computer networking and optical communications is a Multi-port multi-protocol system designed by Ciena that supports TDM / WDM / GigE / 10G / 40G and 100G ports. Backordered. Clearly doing more of the same only increases OPEX due to expensive spares and higher maintenance, hard-to-find legacy skill sets, and manual operations. The 8700 W AC-input power supply is limited to reduced wattage ratings when it is installed in the following Catalyst 6500 series chassis: Note The power supply will not power up if you attach only one power cord and the power cord is connected to low-line (110 VAC nominal) source AC. Two control wires from an external relay controller box attach to either positions 1 and 2 or positions 2 and 3. The following table explains the differences between the two modes. The 1400 W AC-input power supply (PWR-1400-AC) can be installed in the Catalyst 6503 switch and Catalyst 6503-E switch chassis only. 1.For use with the Catalyst 6503 and Catalyst 6503-E switches only. Part #/HECI Mfg Qty Available Description (Random) 134-0106-950: CIENA: 8: COREDIRECTOR OPT MOD: NTK538UJ: CIENA: 18: OME 6500 100G OTR WL3E PREM CBAND LR4 MULTIRATE CIRCUIT PACK The 6000 W AC-input power supply, shown in Figure A-16, and the 6000 W DC-input power supply, shown in Figure A-17, share the same form factor as the 1000 W, 1300 W, 2500 W, 3000 W, and 4000 W power supplies. At Ghekko, we supply new and refurbished Ciena hardware. Do you want to learn more about Ciena's products? Table A-38 lists the specifications for the 8700 W AC-input power supply. Table A-40 lists the relay controller box relay type, the corresponding power supply terminal block positions, and a description of the power-cycling operation. No relay attached. Exceptional DS1, DS3, E1, E3, OC-3/12/48/192, STM-1/4/16/64, and 10/100/1GbE/10GbE, 40GbE/100GbE density to address space constraints, Preserves TDM service, no change to customer end or revenue, customer experience, and tariffs, Launches new Packet and CE services, including MEF CE 3.0-certified for E-Tree, E-Line, E-LAN, E-Access, and E-Transit, Features hardware-assisted packet OAM capabilities for guaranteed SLA differentiation, Offers Zero-Touch Provisioning (ZTP) for rapid, secure, and errorfree turn-up of packet services, Includes advanced packet synchronization and multi-layer protocol support, Integrates line-rate Service Activation Testing capabilities, Includes Ciena’s MCP multi-layer provisioning support for end-to-end network management control and planning, Offers flexible low-power configuration options with redundant power supply (DC) and fan modules, A Path to a Modern and Versatile Government Broadband Network, Ciena at SCTE Cable-Tec - Wayne Hickey Interview, Elegant Migration from TDM to a Modern Packet Network, Solving the TDM-to-Packet Migration Challenge, Blueprint for Utility Network Modernization: Ciena's 6500 PTS.