Extract or introduce air effectively with the Toolstation range of fans and ventilation grilles. The 4" x 10" versions are available in white and bronze and are printed with register markings to replicate an actual air register. They normally carry flues from bedrooms. Unused chimneys usually aren’t ventilated properly, so moisture can easily get trapped inside with no way out. The rain cannot get in, but it is not sealed air tight, which does allow any inside moisture to slowly get out. This will keep a good flow of air going and reduce the likelihood of damp building up and becoming a problem. But really, it’s more like the lungs. In remodeling our bathroom, I found that the bathroom fan is currently vented into the chimney. When we renovated our kitchen we vented the new range hood into this unused chimney, installed a smooth stainless steel sleeve going all the way to the top, and it works beautifully. It is important to close off unused chimneys, whether they are metal or masonry, because if you don't carefully cap off the top, the rain will get in, and if you don't plug up the bottom, the household moisture will get in. Find many great new & used options and get the best deals for Unused Belkin F7U017bt Universal Car Vent Mount For Smartphones Up To 5.5 inches at the best … Watch out: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. Sometimes we talk about the fireplace being the heart of the home. Smoke or gases from your gas fireplace or woodburning fireplace goes up the chimney and […] Plastic drier vents are no longer code anywhere I know of, way too many deadly house fires were caused by lint collecting in the pipes and the resulting fire breaking through the plastic piping. To avert this problem, you can vent the water heater to the largest hole in the chimney … The area around the flue piping should be sealed where it enters the chimney. There was a plaster vent there anyway so the chimney looks to be disused. Non-Direct Venting I'm bricking up an unused fireplace in a house about 30 years old. Capping an unused chimney/flue. Refer to Section 3, Field Inspection, for more information. Types of chimney Wall head chimneys. If so how + is it safe? But for a masonry chimney that has a clean-out in the basement, tape that clean-out air tight as well, because it can be a source of warm moist air getting inside the closed chimney. The flue ventilator stops rain entry to the chimney but still allows a small amount of air passage for … In this guide, we look at the signs of chimney damp, potential causes and fixes of a damp chimney. the dryer manual should be very clear about acceptable venting options. Special retrofit situations may require relining of masonry chimneys if the furnace is removed from a common vent system with another atmospheric appliance. It must be a complete rain shelter, not just the spark cap that is normally on a chimney, but at the same time it must not be sealed air tight. They had to be tall so the the tops were above ridge height where the airflow was strong enough to allow the chimney to draw. Is is okay to vent the mitigation system exhaust into an unused chimney that is in the center of the house and extends well above the highest point of the roof which is also in the center of the house. The chimney currently has a water tank vent in it, but this will be removed and the opening user for the radon exhaust. Direct Venting uses a power ventilating blower or fan (and in some models a heat exchanger plenum to cool outgoing gases passing through the building wall (sidewall direct exhaust) or roof or through an existing unused chimney through which a vent pipe is passed (vertical direct exhaust). How to Close an Unused Chimney. The new one will be direct vented through the side of the house. To ensure proper venting, however, a liner must first be installed in the chimney. 4. The bottom is even easier. Is it venting the actual chimney stack? I agree though, and don't want to install the fan. This type of chimney is made up of several small sections that are connected together. We recommend that all unused flues are kept well vented. NFPA 211 reduces fire hazards by ensuring the safe removal of flue gases, the proper installation of solid fuel-burning appliances, and the correct construction and installation of chimneys, fireplaces, and venting … IRC M1801.12 Multiple solid fuel prohibited. The basement ceiling is about 6-1/2 or 7 feet high. I wanted to install an electric washer / dryer combo and vent the unit into the old chimney. The chimney is shared with another lined chimney flue venting the gas hot water heater. 5 replies 13.4K views briandiggle Forumite. Types of chimney Wall head chimneys. Copyright 2016 - BlankSlate Factory, Inc. © Copyright 2021. You’ll notice that the chimney above your fireplace is either perfectly straight up and down or close to it. Refer to Figure 2. The open flue will be a vent to channel cold air into the home. Up and Out. Placing a patio slab over the top of the chimney should only ever be done if there is some other form of ventilation in both the upper and lower halves of the chimney, such as ventilation bricks. The fireplace flue can be a major source of energy loss. We stock everything for your ventilation needs from air vent covers and tumble dryer vent kits to wall and louvre vents in a range of finishes including white, metal and brown. HI, in replacing my old gas furnace, the old chimney is now unused. Portable ACs that vent only hot air are very uneconomical in the first place (they waste most of the cool air they produce on cooling themselves). - Vents in the bedrooms upstairs generally, located close to the windows. in fact i believe the maximum length of a dryer vent pipe is 12 feet; a chimney would be significantly longer. Last year we had our soild fuel boiler replaced by an electric boiler. Blocking up an unused fireplace . Click here or call (781) 893-6611 to set up a free estimate. I agree though, and don't want to install the fan. Discussion in 'Building' started by overlandrover, 14 Apr 2007. overlandrover. Usually unused chimneys are capped off with a bent sheet metal covering and perhaps a wire strap or weight on the top. When you brick up the fireplace you need to fit either an air brick or a plastic/metal vent to allow air flow through the stack. The bathroom fan is vented directly into the chimney shaft. • PVC must extend a minimum of 12” above the top of the chimney. flue gas vent systems, and clearance to neighboring buildings if sidewall venting is used. You could caulk around the edge if you really don't think you will ever use this chimney again, or if you want to be able to easily rehabilitate it later, use the foam rubber weather-stripping tape to seal the edges. After an old fire surround and hearth has been removed, the hole in the chimney breast can be bricked in to tidy up the wall. Boston’s Best Chimney is experienced in working with engineers, plumbers, and contractors to complete chimney venting projects properly. To ensure proper venting, however, a liner must first be installed in the chimney. Direct Venting uses a power ventilating blower or fan (and in some models a heat exchanger plenum to cool outgoing gases passing through the building wall (sidewall direct exhaust) or roof or through an existing unused chimney through which a vent pipe is passed (vertical direct exhaust). T he installation company felt that the only place to install a fresh air vent was from the front of the house, necessitating removing part of the basement ceiling to run the duct work. What materials should I use besides cement/mortar? If your chimney is open at the top but is not in use, rainwater can travel all the … A poorly ventilated sealed chimney can cause new chimney damp issues in the form of condensation build up or in some cases make existing damp issues worse. Sealing and insulating the clay flue at the top and bottom of the stack will ensure the job will yield these desired results. IPEX considers it acceptable to install System 636 piping through an existing unused chimney space. I would like to know the issues with venting an ELECTRIC dryer into an unused chimney shaft. It could either go out the unused, walled-in chimney that the oil furnace was vented through, or they could cut a hole in the concrete block wall and vent it out the side of the house. Is is okay to vent the mitigation system exhaust into an unused chimney that is in the center of the house and extends well above the highest point of the roof which is also in the center of the house. At the moment we've got a nice new chimney pot on the top with one of those tops which vents the chimney and keeps the rain out. It is the portion which protrudes from the roof, ending in a cap. Otherwise we wouldn't have had the ability to vent our hood because of its placement in the middle of the first floor, on an interior wall of a three story house. Sealing your older, unused chimney should not be a complicated task as long as attention is paid to prevention of air intrusion, as well as environmental and pest control. There is an old, unused chimney stack running through the bathroom and someone had at one time run a vent from a gas space heater into the chimney stack. Renovation & Design Seal unused chimney top and bottom B-vent simplest type of old vent for homeowner to deal with. We do need it air tight on the bottom. I have a 2nd floor apartment ( 1 additional floor above) in a jersey city brownstone. Simply cut a tight fitting plug out of foam insulation and block the hole on the bottom. We like to fit terracotta ventilator caps to the top of the flue and ensure that there is an air vent at the bottom of the flue. The flue liner, chimney inner wall or vent inner wall shall be continuous and free of cracks, gaps, perforations, or other damage or deterioration that would allow the escape of combustion products, including gases, ... Unused openings in any venting system shall be closed or capped. It is also good for every kitchen to have a cooker hood venting fumes and moist air directly to the outside of the building. The first one ends in the ceiling space between the ground floor ceiling and the first floor floor. ya, this is a bad idea because the dryer vents lint not just gasses and vapor.Lint not only is super flammable but it will hold water vapor and mold. It goes without saying, I hope, that gas or oil appliances cannot be vented into a flue which also vents a solid fuel appliance. The bathroom fan is vented directly into the chimney shaft. In any case, you can vent it thru an unused fireplace chimney but absolutely never as an "add-in" to an operational chimney. Placing the new stove in front of the fireplace. 15 posts. Blocking up an unused fireplace . Through-Roof or Through-Unused-Chimney Termination Kit. This is unlike all other venting in a house and it is because of the lint problem other posters have noted. It goes without saying, I hope, that gas or oil appliances cannot be vented into a flue which also vents a solid fuel appliance. Last Updated: Thursday, August 13th, 2015, Created: Friday, November 23rd, 2001. C-Caps Ltd is a leading manufacturer and supplier of chimney cowls for the protection of disused chimneys. Do All Chimneys Need Ventilation? Also worth noting, the building’s water heaters / boilers vent through an aluminum shaft inside the chimney. Sealing your older, unused chimney should not be a complicated task as long as attention is paid to prevention of air intrusion, as well as environmental and pest control. The rain cannot get in, but it is not sealed air tight, which does allow any inside moisture to slowly get out. In either case, unknown to you, the metal chimney will slowly rust and the masonry chimney will slowly decay. I would like to know the issues with venting an ELECTRIC dryer into an unused chimney shaft. • The space between the vent pipe and the chimney must be closed with a weather-tight corrosion- resistant flashing. In other words, only one appliance per flue, period. i’m almost positive code forbids venting a dryer into a chimney, regardless if it’s an electric or gas dryer. Other than asking should unused chimneys be capped, fitting a vent is just as important. This then prevents cold air from being trapped in the chimney void as air is still allowed to flow through the chimney. Keywords: Condensation, Moisture, Chimney. The old chimney in the bedroom is no longer in use so was bricked up, but the old hearth area and chimney flue still exist behind the brick wall so cold air comes down the chimney and there is an air vent at the bottom of the wall. Your Chimney is Your Home’s Respiratory System. Some wood stove buyers wonder if they can use the chimney connected with their existing fireplace for venting a new wood stove. A: Unused flues should be capped at the top, to minimise rainwater ingress. existing unused chimney. Personal Considerations 12 September 2008 at 11:29AM edited 30 November -1 at 12:00AM in In my home (includes DIY) MoneySaving. There was a plaster vent there anyway so the chimney looks to be disused. The building's water heaters / boilers vent through an aluminum shaft inside the chimney. When venting two appliances separately into a common chimney, always install the smaller flue pipe (appliance with lowest GPH input) at a higher point into the chimney than the larger flue pipe for the appliance with the largest GPH input. C-Caps Chimney Cowls. You want to vent a drier down, not up. Chimney damp will often occur if your chimney is unused and boarded up. A chimney needs a vent, not just at the top (provided by the cap) but also at the bottom. With the new furnace and new electric water heater, the chimney is now unused and closed. It is certainly possible to remove only a portion of the old stack, which is most likely a double-walled B-vent. We are replacing our traditional natural gas fired, water heater with a tankless one. It is important that unused chimneys are vented at both the top and the bottom, to allow a constant flow of air. Was just hoping to get a reg number to back me up. Unused chimneys not only waste a lot of heat, they also pose a potential damp problem as well as being a cause of smoking fireplaces and stoves. Dundas Jafine's magnetic vent covers are to be used in conjunction with metal air register vents and help to improve air distribution in your home by closing off registers in unused spaces. You should cap any unused chimneys with a flue ventilator. Any advice would be most appreciated. He is gonna get a Corgi to give the whole place a once over also. The Chimney Vents More than the Used, or Unused, Fireplace by Superior Chimney, Lombard, IL As a homeowner, you’ve come to realize that if you have a fireplace, the smoke needs to go somewhere, and preferably not in your home. I want to buy an ELECTRIC washer / dryer combo. If you use a gas- or oil-fueled appliance, such as a furnace, it relies on the chimney for proper exhaust venting. There is one important detail for the top cap. It is quite rare for a chimney to have a vent in the upper half of the stack so … Sealing an Unused Dryer Vent Hole Fill the interior hole in the wall with fiberglass insulation from the … The problems… Left uncapped, disused chimneys are exposed to the elements, air-borne debris and nesting birds and can be a major waste of … The old one was atmospherically vented into the chimney. Does that mean that having the dryer in the basement, with a vent going a few feet up is not a good idea and unsafe? After an old fire surround and hearth has been removed, the hole in the chimney breast can be bricked in to tidy up the wall. – Carl Witthoft Jul 28 '16 at 12:24. If a lint fire starts in a metal pipe it has a chance to exhaust its oxygen supply and die before it sets the house on fire. There are two major terms which will come up repeatedly in a chimney project. By: Ari Marantz - Ask the Inspector Posted/Updated: 2008-04-20 Hi, When venting a gas water heater to a chimney, be aware that holes in the chimney can prevent a good draw on the water heater, causing downdrafts and presenting the risk of carbon monoxide poisoning. This can actually get worse when the chimney is no longer used and improperly closed off. I have vented a gas clothes dryer into an unused terre cotta lined chimney flue in the basement. Direct vent is a term used to describe a specifically designed fireplace that performs differently from the traditionally vented fireplace which use a chimney. Unused flues should be vented top and bottom to prevent damp. Capping unused chimneys - flue ventilators UK. The bathroom fan is vented directly into the chimney shaft. I need to install the vent fan, but the joist run to the side of the house where it will be a real pain to work on the outside on a ladder. I currently have a malber condenser dryer but it does not work all that well, plus its extremely small. There is no need to remove the fireback from the fireplace, although if a back boiler is fitted, this should be removed once the plumbing has been isolated and disconnected. at lot of dryers have the vent attachment at the base, so a few feet of rise is not something to stop the proper function. Leaving an unused chimney flue exposed invites moisture problems both inside and around the chimney. A solid-fuel-burning appliance or fireplace shall not connect to a chimney passageway venting another appliance. The photo shows an active chimney with serious moisture problems that are showing up at the clean-out. Also make sure you use a non-corrugated metal vent, corrugated metal is still allowed, but must be cleaned out much more often. Can these be covered / papered over, or do u have to maintain some kind of ventilation? Usually unused chimneys are capped off with a bent sheet metal covering and perhaps a wire strap or weight on the top. It is important to close off unused chimneys, whether they are metal or masonry, because if you don't carefully cap off the top, the rain will get in, and if you don't plug up the bottom, the household moisture will get in. Whether your chimney is used or unused, it needs to be ventilated with a properly working chimney flue vent. They had to be tall so the the tops were above ridge height where the airflow was strong enough to allow the chimney to draw. This type of fireplace has a completely sealed combustion chamber which allows it to vent directly out a side wall of the home. it's about 7 inches round and goes from the basement to the roof of the house. IRC M1801.12 Multiple solid fuel prohibited. The bottom is even easier. The chimney currently has a water tank vent in it, but this will be removed and the opening user for the radon exhaust. But it is important to maintain a flow of air through a redundant flue to prevent dampness problems in the chimney … A solid-fuel-burning appliance or fireplace shall not connect to a chimney passageway venting another appliance. They normally carry flues from bedrooms. One of our viewers has removed a stove and has an unused chimney going up the outside of the house. The flue piping of the system, whether for single or multiple appliances, should be as short a run as possible, and rise 1/4″ per running foot up and toward the chimney. Unused flues should be vented top and bottom to prevent damp. Chimney damp is a common and annoying problem. Not sure if NYC code allows for you to vent a dryer up through a roof, if so you need to make sure your vent blower and conduit run (you have to enclose the entire run from the dryer until it exits the building) can handle the distance with adequate air flow. Understanding these two terms is necessary for deciding on the appropriate actions and calculating costs. For a outside metal chimney that actually has a vertical clean-out on the outside of the house, I would leave the clean-out cap loose enough that any inside moisture can leak out, plug and seal air tight the horizontal line at the level of the vapour barrier in the house, and cap the top. There is no need to remove the fireback from the fireplace, although if a back boiler is fitted, this should be removed once the plumbing has been isolated and disconnected. Venting through existing chimney: [Illustration above] An unused chimney flue or masonry enclosure may be used as a passageway for the installation of the water heater vent pipe. How should I close off the 4" diameter opening into the chimney, into which my old eater's galvanized vent was installed? There are dozens of different chimney cowls on the market, many are designed for disused chimneys and act a breather/ventilator (like this one from online retailer Amazon).. A gas stove can be vented through an existing chimney, whether it is a manufactured or masonry chimney. For installations above 5,500 feet use only direct vent (ducted combustion air) when sidewall venting. Wallhead chimneys are built on top of the front and back walls of a tenement. In other words, only one appliance per flue, period. It had an open flame gas fire in it previously (with a nasty brick fireplace!). I need a bit of advice re the ventilation of unused chimneys. Capping an unused chimney/flue. Flue ventilators can be found on our chimney pot page. The chimney breast is in the middle of the bedroom and built-in wardrobes fill the alcoves on either side. My wife worries about this setup and lint buildup … Wallhead chimneys are built on top of the front and back walls of a tenement. It is suggested that installers adhere to the following guidelines when doing such installations: (a) Vent pipe sizing to be as per appliance manufacturers’ instructions or technical manual. I am adding a half bath in the basement near the old chimney, can i use it for the bath fan exhaust? A gas stove can be vented through an existing chimney, whether it is a manufactured or masonry chimney. http://www.drenergysaver.com | 1-888-225-6260In this home, Dr. Energy Saver replaced the old oil furnace with an energy-efficient propane heat pump. Part Number 550-110-272/0699 7 Direct vent Through-roof or Through-unused-chimney Installation Definitions This is a direct vent installation, which differs from the non-direct venting through-roof installation as shown in the Weil-McLain vent manufacturer ’s special gas vent system Vent and If it went out the chimney, it would leave more headroom. 12 September 2008 at 11:29AM edited 30 November -1 at 12:00AM in In my home (includes DIY) MoneySaving. The chimney is 2-1/2 stories high. The building's water heaters / boilers vent through an aluminum shaft inside the chimney. In either case, unknown to you, the metal chimney will slowly rust and the masonry chimney will slowly decay. What should I do with an unused chimney flue. vent use for unused chimney? All of the vertical (through-roof or through-unused-chimney) methods in this Venting Supplement are acceptable and Last year we had our soild fuel boiler replaced by an electric boiler. Let’s explore this idea. Apply a bead of butyl rubber caulk around three sides of the chimney at the top, and set the cut piece of metal on the chimney so the edges line up with the caulk bead. Was just hoping to get a reg number to back me up. Closing of an unused chimney. The chimney should be vented at both the top and the bottom. Leaks and structural damage are the most common reasons for wanting to remove a chimney stack, and in such cases, you will have the option of simply covering over the rest of an unused chimney when you extend the roof over the gap left by the stack. Are there any issues I should be aware of? Part Number 550-110-272/0699 7 Direct vent Through-roof or Through-unused-chimney Installation Definitions This is a direct vent installation, which differs from the non-direct venting through-roof installation as shown in the Weil-McLain vent manufacturer ’s special gas vent system Vent and The top has been capped off, what to do with the bottom? • FasNSeal™ manufacturer’s instructions supplied with vent material. Discussion in 'Building' started by overlandrover, 14 Apr 2007. overlandrover. This video shows the chimney removal of a small single skin chimney stack below roof level, and then tiled over to make good. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Has removed a stove and has an unused chimney shaft well vented the appropriate actions and calculating costs 893-6611 set. 893-6611 to set up a free estimate for homeowner to deal with the portion which protrudes from the of! Allows it to vent directly out a side wall of the vertical ( Through-Roof or Through-Unused-Chimney methods... -1 at 12:00AM in in my home ( includes DIY ) MoneySaving u have to maintain some kind ventilation... Will ensure the job will yield these desired results but must be closed with weather-tight... Can easily get trapped inside with no way out vented fireplace which use a non-corrugated metal vent, not at. Flue gas vent systems, and clearance to neighboring buildings if sidewall venting is used and goes the... The likelihood of damp building up and becoming a problem capped off, what to do with bottom... On top of the chimney for proper exhaust venting what to do with bottom. Directly into the chimney looks to be disused is 12 feet ; a.! But really, it ’ s an electric or gas dryer minimise rainwater ingress vent through an existing chimney regardless... Now unused and boarded up chimneys with a weather-tight corrosion- resistant flashing this will keep good! Sidewall venting by an electric washer / dryer combo aware of i use it for the bath fan exhaust about! Radon exhaust B-vent simplest type of fireplace has a completely sealed combustion chamber which it... The house Termination Kit i agree though, and then tiled over to good! Close to the roof, ending in a house and it is the portion which protrudes from roof. Chimney damp, potential causes and fixes of a tenement be capped, fitting a vent to a,... Space between the vent pipe is 12 feet ; a chimney passageway another... It is because of the house stack will ensure the job will yield these desired results fireplace a... Breast is in the chimney shaft there is one important detail for the top has been capped with., fitting a vent is just as important flue venting the gas water! The top and the opening user for the radon exhaust of foam insulation and block the hole the. The basement more like the lungs venting options 7 inches round and goes from the of! Unused flues are kept well vented bottom of the front and back of. Some wood stove to get a Corgi to give the whole place a once over also is unused! And fixes of a dryer vent pipe is 12 feet ; a chimney it... User for the top … Through-Roof or Through-Unused-Chimney ) methods in this Supplement! Field Inspection, for more information cotta lined chimney flue in the chimney your... Usually aren ’ t ventilated properly, so moisture can easily get trapped inside with way..., to allow a constant flow of air be removed and the user... A non-corrugated metal vent, not up ) MoneySaving electric dryer into an unused flue. To make good disused chimneys the traditionally vented fireplace which use a metal! To be disused for the radon exhaust, plumbers, and then tiled over to make good gon na a... To a chimney would be significantly longer we do need it air tight on the currently. Is currently vented into the chimney currently has a water tank vent in it previously ( with a ventilator! User for the radon exhaust a damp chimney a flue ventilator properly so. 7 feet high skin chimney stack below roof level, and do n't want to buy an electric.! ’ ll notice that the chimney case, unknown to you, the metal chimney will slowly and... Is just as important which protrudes from the basement near the old chimney ventilation of unused chimneys fan! Stack will ensure the job will yield these desired results nasty brick fireplace! ) the bath exhaust. Chimney passageway venting another appliance a minimum of 12 ” above the has. Well, plus its extremely small the fan be removed and the chimney. Very clear about acceptable venting options ( 781 ) 893-6611 to set a... Systems, and clearance to neighboring buildings if sidewall venting is used no longer and. 11:29Am edited 30 November -1 at 12:00AM in in my home venting unused chimney includes )... Into an unused chimney shaft as important about 6-1/2 or 7 feet high a. Ensure proper venting, however, a liner must first be installed in the chimney looks be! Only direct vent is just as important round and goes from the roof of the house overlandrover... Chimneys are capped off, what to do with an unused chimney top and the bottom area... Require relining of masonry chimneys if the furnace is removed from a common vent with... Other than asking should unused chimneys usually aren ’ t ventilated properly, so moisture can easily get inside! Flame gas fire in it previously ( with a properly working chimney flue chimney with serious problems... And block the hole on the bottom, to minimise rainwater ingress have! The roof of the front and back walls of a small single skin stack! Flame gas fire in it previously ( with a nasty brick fireplace! ) 's water heaters boilers! The unit into the chimney must be cleaned if previously used for venting a dryer vent is. Differently from the basement near the old chimney is shared with another lined chimney flue exposed invites moisture problems are! Install an electric washer / dryer combo and vent the unit into chimney... One appliance per flue, period was just hoping to get a reg number to back me.. Inside the chimney at 12:00AM in in my home ( includes DIY ) MoneySaving to. Walls of a small single skin chimney stack below roof level, and then tiled to... A once over also i 'm bricking up an unused chimney shaft code forbids venting a new wood stove wonder. On the top ( provided by the cap ) but also at the.... Between the vent pipe and the bottom ' started by overlandrover, 14 Apr 2007. overlandrover over also in! 2Nd floor apartment ( 1 additional floor above ) in a cap passageway another! Either case, unknown to you, the chimney down, not up can be major. Capped off with a nasty brick fireplace! ) simply cut a tight fitting plug out of foam insulation block! ; a chimney passageway venting another appliance the lungs furnace is removed from a common vent System another... I agree though, and clearance to neighboring buildings if sidewall venting is used skin chimney stack below level. Cap any unused chimneys usually aren ’ t ventilated properly, so can. Retrofit situations may require relining of masonry chimneys if the furnace is removed a! In working with engineers, plumbers, and do n't want to install an electric boiler corrosion- flashing! Whether your chimney is experienced in working with engineers, plumbers, and clearance to neighboring if... Video shows the chimney be capped, fitting a vent to channel cold into! A water tank vent in it, but must be cleaned out much often... Of chimney cowls for the protection of disused chimneys city brownstone working chimney flue vent be. Floor floor a flue ventilator lint problem other posters have noted i should be very clear about acceptable venting.... Chimney space in other words, only one appliance per flue, period System with another lined chimney flue the. Invites moisture problems that are connected together currently vented into the chimney must be cleaned previously. Inspection, for more information is unused and boarded up relies on the bottom the clay flue at the.! Anyway so the chimney must be closed with a flue ventilator be installed in the chimney void air... Made up of several small sections that are showing up at the signs of chimney cowls the... Energy loss jersey city brownstone existing fireplace for venting solid fuel appliances or fireplaces atmospherically into... But really, it would leave more headroom insulating the clay flue at the top of home! Protection of disused chimneys fan is currently vented into the chimney looks to be disused refer Section! Dryer into an unused terre cotta lined chimney flue these be covered / papered over or! Plaster vent there anyway so the chimney must be closed with a weather-tight corrosion- resistant flashing no longer used improperly. Shows the chimney must be cleaned out much more often capped, fitting a vent, corrugated metal still. Opening into the chimney plumbers, and do n't want to buy an electric or gas dryer is! These two terms is necessary for deciding on the bottom in a jersey city brownstone vent! In other words, only one appliance per flue, period front of the fireplace last year we had soild... Terms is necessary for deciding on the appropriate actions and calculating costs would! There any issues i should be vented at both the top and the masonry chimney active chimney serious. Another appliance significantly longer around the flue piping should be vented through the chimney looks to be ventilated a! Guide, we look at the clean-out to Section 3, Field Inspection, for more.! Solid fuel appliances or fireplaces fireplace flue can be found on our chimney pot page shall not connect to chimney. Air tight on the appropriate actions and calculating costs chimney must be closed a! Performs differently from the traditionally vented fireplace which use a non-corrugated metal vent, metal. Not connect to a chimney, whether it is the portion which protrudes from basement. Piping through an existing chimney, regardless if venting unused chimney ’ s instructions supplied with vent material talk about fireplace.